E1
Indoor/Outdoor Communication Error
- Turn off power and restart the system.
- Inspect communication wiring between units.
- Check connectors for corrosion or looseness.
- Replace control board if communication fails.
E9
PCB Communication Error
- Inspect main PCB wiring connections.
- Power cycle the air conditioner.
- Check for damaged communication cables.
- Replace faulty PCB if needed.
Sensor Errors
E2
Indoor Coil Sensor Fault
- Inspect indoor coil sensor wiring.
- Test thermistor resistance values.
- Check for loose connectors.
- Replace sensor if readings are incorrect.
E3
Outdoor Coil Sensor Fault
- Inspect outdoor sensor wiring.
- Check sensor placement on coil.
- Test resistance with multimeter.
- Replace faulty outdoor sensor.
Compressor Protection Errors
E4
Compressor Overload Protection
- Allow compressor to cool before restart.
- Clean condenser coil for proper airflow.
- Check refrigerant pressure levels.
- Inspect compressor capacitor and relay.
E5
Overcurrent Protection Triggered
- Check power supply voltage stability.
- Inspect compressor current draw.
- Verify electrical wiring condition.
- Replace damaged electrical components.
Refrigerant System Errors
E6
Refrigerant Leakage Detected
- Inspect refrigerant lines for leaks.
- Check flare connections and valves.
- Contact certified HVAC technician.
- Recharge refrigerant after repair.
Fan System Errors
E7
Fan Motor Error
- Inspect fan blades for obstruction.
- Check motor wiring connections.
- Test fan motor operation.
- Replace fan motor if defective.
Memory & Control Errors
E8
EEPROM Failure
- Power cycle the unit.
- Inspect PCB for moisture or damage.
- Check EEPROM communication lines.
- Replace control board if fault persists.
System Protection Messages
EC
System Protection Mode Active
- Allow unit to stabilize and cool down.
- Check for airflow restrictions.
- Inspect sensors and refrigerant levels.
- Reset system after correcting issue.